 Objectives: To investigate auditory dysfunction in patients with tinnitus and normal hearing thresholds using two sensitive audiological measures. Design: The study was designed to investigate the characteristics of Audioscan and DPOAE tests in tinnitus patients with normal hearing thresholds. Audioscan and DPOAE notches were analysed and compared. All tests were performed in a sound-treated chamber or in a sound-treated room. Study sample: Forty-five tinnitus patients with normal hearing thresholds were examined following a written clinical protocol. Results: The averaged hearing levels obtained from tinnitus participants were significantly worse at high frequencies than those derived from the normative data. There was a significantly higher prevalence of Audioscan and DPOAE notches, whose central frequencies matched tinnitus frequencies in the mid-frequency regions, but not in the low- and high-frequency regions. A significant correlation was found between the centre frequencies of the Audioscan notches and the DPOAE notches from 500 to 4000 Hz. Conclusion: Tinnitus in different frequency regions may be associated with different underlying mechanisms of tinnitus generation. Some negative results on the Audioscan and DPOAE notches matching tinnitus pitches may be due to a limited set of discrete frequencies used for the tinnitus pitch matching test. 

Funding

W.S. Ishak was supported by Ministry of Higher Education (MOHE) Malaysia and Universiti Kebangsaan Malaysia (UKM) as part of her PhD research at the University of Bristol, UK

History

Published in

International Journal of Audiology

Publisher

Taylor & Francis

Version

  • AM (Accepted Manuscript)

Citation

Zhao, F., Stephens, S.D.G., Ishak, W.S. and Meyer-Bisch, C. (2014) 'The characteristics of Audioscan and DPOAE measures in tinnitus patients with normal hearing thresholds', International Journal of Audiology, 53(5), pp.309-317

Print ISSN

1499-2027

Cardiff Met Affiliation

  • Cardiff School of Sport and Health Sciences

Cardiff Met Authors

Fei Zhao

Cardiff Met Research Centre/Group

  • Speech, Hearing and Communication

Copyright Holder

  • © The Publisher

Language

  • en

Usage metrics

    Population Risk & Healthcare - Journal Articles

    Categories

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC